ATMI
- Allowed fluid densities: 0,95 à 1,05 g/cm
- Cut-out power: 16 (6) A
- Maximum pressure: 3,5 bars
- Maximum temperature: 70 °C
- Protection index: IP 68
- Housing: Copolymer polypropylene
- Type of cable: PVC 3 x 0,75 mm²
- Float weight without cable: 400 g
- Switching angle: 10°
- For non agitated liquids
- Polypropylene casing
- EPDM cable
- Power supply: 12 ... 250 V
- Switching power: 16(6)A
- Ballast integrated in the float
- Dimensions: 140 mm - Ø 70 mm
- Switching angle: +/- 10°
- Allowed fluid density: 0,95 to 1,05
- Power supply: 12, 24, 48 VAC /VCC - 250 VAC /VCC 50/60 Hz
- Cut out power: 16 (6) A (16 A resistive; 6 A inductive)
- Maximum pressure: 3,5 bars
- Allowed temperature: 85 °C
- Supply voltage: 220 V
- Sensitivity: High up to 70 KOhm
- Operating temperature: - 10 à + 55°C
- Number of probes max.: 3
- Response time: 100 ms
- Electrical charge on contacts: 5A-240V
- Supply voltage: 220 V
- Sensitivity: Average of 0 to 10 KOhm
- Operating temperature: - 10 à + 55°C
- Number of probes max.: 7 Response time: 100 ms
- Electrical charge on contacts: 5A-240 V
- Power consumption: 10 VA
- Probe voltages: 24 VA
- Probe weight: 45 g
- Dimenssion:72 x 90 X 60 mm
- Allowed fluid densities: 0,80 à 1,10 g/cm³
- Electric characteristics: 250 VCA /VCC 50/60 Hz
- Cut-out power: 20 (8) A
- Maximum pressure: 4 bars
- Maximum temperature: 90 °C
- Protection index: IP 68
- Housing: Copolymer polypropylene + HR HY
- Type of cable: HR HY
- Float weight without cable: 295 g
- Supply voltage: 220 V
- Sensitivity: Modulable up to 100 KOhm
- Operating temperature: - 10 à + 55°C
- Number of probes max.: 3
- Response time: 100 ms
- Electrical charge on contacts: 5A-240V
- Supply voltage: 220 V
- Sensitivity: Normal 0 to 5.6 KOhm
- Operating temperature: - 10 à + 55°C
- Number of probes max.: 3
- Response time: 100 ms
- Electrical charge on contacts: 5A-240 V
- Power consumption:3 VA Probe voltages: 10V
- Probe weight: 45 g
- Dimenssion:53 x 95 X 58 mm
- Switching angle: 165°
- For heavily agitated liquids
- Polypropylene casing
- EPDM cable
- Power supply: 50 ... 400 V
- Switching power: 20(8)A
- Stainless steel ballast - 230 gr
- Dimensions: 152 mm - Ø 95 mm
- Omni Directional Operation
- Switching angle+/- 110º
- Maximum pressure 3.5 bar
- Allowed Fluid Density 0.70 to 1.15
- 20A resistive - 8A inductive
- 1, 3, 5, 10 and 20m Options
- Important specification: Avoids the deterioration of the cable
- Maximum temperature: 85°C
- Housing: Polyamide
- Weight: 25 g
- Temperature compensation: 0 ... + 40°C
- Output signal: 4/20mA
- Electric characteristics: 8 - 36 VDC
- Hystérésis: 0,05%
- Type of cable: PU
- Output signal: 4/20mA
- Electric characteristics: 8 - 36 VDC
- Hystérésis: 0,05%
- Type of cable: PU
- 2 channels – 2 outputs
- Cable error detection
- Up to SIL 3 in accordance with CEI 61508
- Input from area 0 (Area 20), safe in installation or in Area 2.
- Galvanic isolation of 3 ports of the circuit, input, outputm, power
- Installation on a DIN rail, with or without Power Bus.
- Power supply 24 Vdc (18 to 30 Vdc)
- Allowed fluid densities: 0,70 à 1,15 g/cm³
- Electric characteristics: 12,24,48 VCA /VCC - 250 VCA - 50/60 Hz
- Cut-out power: 16 (6) A Maximum pressure: 3,5 bars
- Maximum temperature: 85 °C
- Protection index: IP 68
- Omni Directional Operation
- Switching angle+/- 25º
- Maximum pressure 4 bar
- Allowed Fluid Density 0.70 to 1.15
- 16A resistive - 6A inductive
- 5, 10, 13, 15, 20, 25 and 30m Options
- Omni Directional Operation
- Switching angle+/- 25º
- Maximum pressure 3.5 bar
- Allowed Fluid Density 0.70 to 1.15
- 16A resistive - 6A inductive
- 5, 6, 10, 13, 15, 20 and 25 m Options
Technical Datasheet |
- Aggressive liquids : acids, solvents, corrosive liquids, hydrocarbons, sea water, etc.
- Level control of multiple pumps
- Emptying / Filling function
- Overflow or dry-running protection
- High / low level alarm
- Clear, clean liquids, rain water
- Wastewater, sewage water, charged liquids
- Slightly aggressive liquids (oils, mud, paint, etc.) and more aggressive liquids if equipped with a HR HY cable
- Level control of multiple pumps
- Overflow or dry-running protection
- High / low level alarm
- Tilting Operation
- Switching angle+/- 10º
- Temperature -40º to 85ºC
- Bulk Solids High Level Measurement
- 20A resistive - 8A inductive
- 5, 6, 13, 15, 20 and 30m Options
Technical Datasheet |
- Tilting Operation
- Switching angle+/- 10º
- Temperature -20º to 70ºC
- Bulk Solids High Level Measurement
- 10A resistive - 4A inductive
- 5, 10, 15, 20, 25 and 30m Options
Technical Datasheet |
- Operation mode: By tilting
- Electric characteristics: 240 VCA 50/60 Hz
- Cut-out power: See SOLIBA or SOLIBA EX P
- Maximum temperature: See SOLIBA or SOLIBA EX P
- Protection index: IP 68
- Housing: Cast aluminium
- Type of cable: Neoprene ou HR HY 3X1 mm²
Technical Datasheet |
- Operation mode: by rotation
- Measuring blade speed: 1rpm
- Cut-out power: 15 A
- Maximum temperature: -20 - + 70°C
- Protection index: IP 65 -
- Body: Aluminium
- Float weight without cable: 2,5 kg
- Operation mode: by rotation
- Important specification: ATEX Only in non ATEX area
- Measuring blade speed: 5 rpm
- Electric characteristics: 230 VCA 50/60 Hz Option :24VCA/VDC
- Cut-out power: 2A
- Maximum temperature: -20 - + 60°C
- Protection index: IP 65 - 53
- Vanes: Inoxidable AISI 304 o 316
- Body: Glass fiber reinforced ABS
- Float weight without cable: 800 g
Technical Datasheet |
- Operation mode: By tilting
- Important specification: Allows for the detection for very light products
- Housing material: Stainless steel food 18/10
- Tilt weight without device: 300 g
Technical Datasheet |
- Omni Directional Operation
- Switching angle+/- 20º
- Maximum pressure 5.5 bar
- Allowed Fluid Density 0.70 to 1.15
- 12A resistive - 6A inductive
- 2, 3, 5, 10 and 20m Options
Technical Datasheet |
- Allowed fluid densities: 0,75 à 1,50 g/cm³
- Electric characteristics: 250 VCA - 50/60 Hz
- Cut-out power: 12 (6) A
- Maximum pressure: 5,5 bars
- Maximum temperature: 85 °C
- Protection index IP 68
- Housing: Copolymer polypropylene
- Type of cable: Neoprene
- Float weight without cable: 60 g
Technical Datasheet |
- Allowed fluid density: 0,75 à 1,50 g/cm³
- Electric characteristics: 230 VCA - MAX 60 VA
- Cut-out power: 6 (4) A Maximum pressure: 2 bars
- Maximum temperature: 125 °C
- Protection index: IP 68
- Housing: PVDF Type of cable: PTFE 3 x 0,22 mm²
- Float weight without cable: 90 g
- Allowed fluid density: 0,75 à 1,50 g/cm³
- Cut-out power: Max. 1 A, 60 VA
- Maximum pressure: 1 bars
- Maximum temperature: 150 °C
- Protection index: IP 68
- Housing: PTFE
- Type of cable: FEP
- Float weight without cable: 80 g