Flow Electronic
- Universal input for unit signals
- Pt100, thermocouple, potentiometer, switchable via front-side DIP switch
- 1 or 2 relay outputs
- Universal relay connection
- Adjustable min/max contact function
- Actual value output 4 .. 20mA
- 2-colour illuminated scales for limit value adjustment, colour depends on switch status
- With Pt100 sensors, monitoring of sensor break and short-circuit
- Wide-range mains adapter or 24 V DC
- Functional safety up to SIL2
- Housing width 12.5 mm
- Removal coded terminals
- Carrier rail mounting TS35 EN60715
- Safe galvanic isolation between input / output / auxiliary voltage
- Momentary value indicator and totalisation
- Pulse output with adjustable pulse per volume
- Antivalent outputs
- Analogue output of the momentary value
- Simple guided menu via graphics display
- Signal conditioning – Linearisation – Characteristic adjustment
- Input for standard signals 0/2..10 V and 0/4..20 mA
- Measuring range programmable
- Linearisation and characteristic adjustment programmable via 32 bases
- Automatic input fault detection
- Thermoelements J, K, S
- Pt100 Elements
- 0/2..10 V und 0/4..20 mA
- 4..20 mA analogue output
- Transmitter for electrical signals
- Universal input for standard signals, Pt100, thermocouple, potentiometer
- Configuration via front-side DIP switch
- Wide-range power supply or 24 V DC
- Housing width 12.5 mm
- Removal coded screw terminals
- Carrier rail mounting TS35 EN60715
- Thermoelements J, K, S
- Pt100 / Pt1000 / NTC resistance measurement
- 4..20 mA analogue output
- Universal input for Pt100, Pt1000, thermocouple, NTC and resistance measurement value
- Configuration via front DIP switches
- Analog actual value output 4 .. 20mA
- Zero point and limit value can be adjusted via trim potentiometers on the front
- Wide-range mains adapter or 24 V DCa
- Optional supply via carrier rail bus
- Removable coded screw terminals or optional push-in terminals
- Housing width 12.5 mm
- Carrier rail mounting TS35 EN60715
- Offers intrinsically safe inputs for direct connection of temperature probes
- Simple programming
- 2 alarm outputs
- Pt100, Pt1000 and thermocouple
- Pt100, Pt1000 and thermocouple
- Up to 4 alarm outputs
- LCD display with plain text
- Intrinsically safe use of Pt100 sensors
- Intrinsically safe use of 0(4)…20 mA sensors
- Intrinsically safe use of 4…20 mA, loop-powerd indicators
- Measuring range 0..50 Ω up to 100 kΩ
- Processor technology with 12 Bit AD/DA-converter
- Teach-in programming for start- and end-value
- Increase or decrease output characteristic programmable
- Operation mode indicated by use of a 2-color LED
- Measuring range 100 mbar to 10 bar
- Immersion depth: max. 100 m
- Analog output 4..20 mA
- For drinking-, process-water, oil
- Process temperature -10..+60 °C
- Protection class IP68, depth of immersion max. 100 m
Technical Datasheet |
- Flow transmitter for water and other liquids with integrated temperature measurement
- Fast response timeIntegrated volume meter with preset
- Measuring method without moving parts, no wear
- Stainless steel material coming into contact with medium
- 1 analog output (20 mA / 10 V)
- 2 versatile configurable switching outputsIO-Link interface
- High-resolution graphic LCD Parameters programmable with multifunction ring
- Waterproof all-metal housing (IP67)
- Mineral glass front, scratch-proof and chemically resistant
- Can be used on site for: parameter modification, firmware update, adjustment of inputs and outputs
- Can be connected via USB
- 1/4” or 1/2” Screw in connection
- 2 - 150 cm/s metering range
- 4-20 mA or 0-10V output
- PNP / NPN switch output
- All stainless wetted parts
- Fast response times
- Particularly suitable for extremely high flow rates
- Extremely fast response time: 100 ms
- Measures flow, total consumption, temperature and pressure
- Measurement at high temperatures – max. 200 °C
- Measurement in various gases by selecting gas type, on request
- Can be used in pipes from DN 20 to DN 500
- Installation via 1/2″ ball valve under pressure
- RS 485 interface (Modbus-RTU), 4…20 mA, pulse output as standard
- From 0.4 to 100 l/min flow ranges
- Very fast response time
- High Overload Protection
- High Max Flow
- Low pressure Loss
- Compact Design
- 150c High Temperature Option
- 100 bar High pressure Version Available