Probe Housings


  • Flexible design
  • DN25 / 1” or DN50 / 2”
  • 90° or 180° flow direction
  • Best sensor position
  • Material PVDF
  • High variation of process connections
  • Up to 6 bar and 120 °C
  • DN25 / 1” or DN50 / 2”
  • Flow direction 90° or 180°
  • Stainless steel AISI 316Ti / 1.4571 or ETFE-lined (conductive version as option)
  • Many different variations
  • Up to 16 bar and 140 °C


  • All required connection tubes are integrated
  • Matching fasteners for various probe housing types possible
  • PG29 connection on control unit side
  • Quick and easy installation
  • Additional control tubes for cleaning valves are integrated
  • Available in suitable length
  • Size and color-coded control tubes for confusion-free connection
  • Full automatic measuring points
  • High extension of sensor-lifetime and reducing of servicing efforts
  • Open system - operates with any kind of transmitter
  • Output signals for connecting with PCS
  • Three different cleaning solutions usable
  • Sealing water function
  • Pre- and post-cleaning function
  • Full automatic measuring point
  • High extension of sensor-lifetime and reducing of servicing efforts
  • Open system - operates with any kind of transmitter
  • Output signals for connecting with PCS
  • Three different cleaning solutions usable
  • Sealing water function
  • Pre- and post-cleaning function
  • Optionally with or without cable protection
  • Can be operated by hand up to 2 bar process pressure
  • Protection cage can be adjusted when unlocked
  • Locking of the immersion tube in the end positions “Measurement” or “Service”
  • 76 mm immersion depth (with protection cage extended)
  • Further process connections upon request
  • Robust design, with ball valve
  • Integrated sealing package
  • Automatic locking mechanism at too high process pressures
  • Stainless steel AISI 316L / 1.4404
  • Immersion length up to 700 mm nominal
  • High variation of process connections
  • Applicable up to 12 bar and 130 °C
  • Hygienic design, EHEDG- / 3A-approved process connections
  • Automatic locking system with indicators for measurement- and service position
  • Automatic safety lock while sensor is removed
  • AISI 316L / 1.4404, surface finish Ra<0.78 electropolished
  • High variation of process connections and sealing materials
  • Up to 16 bar and 140 °C
  • Drive unit free of maintenance
  • Robust design, integrated PTFE scraper
  • Usable for DN25 welding socket
  • Extension of sensor-lifetime and reducing of maintenance efforts
  • Automatic safety lock while sensor is removed
  • Usable in ATEX-areas
  • Immersion length 70mm
  • Up to 10 bar and 140 °C
  • Robust design, integrated scraper
  • Automatic locking system with indicators for measurement- and service position
  • Automatic safety lock while sensor is removed
  • Safe handling under higher process pressure due to unique rotary drive
  • PVDF or PEEK
  • High stability protection cage in Alloy for option PVDF
  • Usable in ATEX-areas
  • Robust design, integrated scraper
  • Automatic locking system with indicators for measurement- and service position
  • Automatic safety lock while sensor is removed
  • Safe handling under higher process pressure due to unique rotary drive
  • PP, PVDF or PEEK available
  • Usable in ATEX-areas
  • High stability protection cage in Alloy for option PVDFImmersion length up to 94mm
  • Robust design, integrated PTFE scraper
  • Automatic locking system with indicators for measurement- and service position
  • Automatic safety lock while sensor is removed
  • Safe handling under higher process pressure due to unique rotary drive
  • Stainless steel AISI 316L / 1.4404 or Alloy
  • Immersion length up to 90mm
  • Usable in ATEX-areas
  • Robust design, integrated scraper
  • Automatic locking system with indicators for measurement- and service position
  • Automatic safety lock while sensor is removed
  • Stainless steel AISI 316L / 1.4404 or Alloy
  • Usable in ATEX-areas
  • Immersion length up to 207mm
  • High variation of process connections and sealing materials
  • Up to 16 bar and 140 °C
  • Drive unit free of maintenance
  • Easy retrofit to pneumatic drive prossible
  • Robust design, integrated scraper
  • Automatic locking system with indicators for measurement- and service position
  • Automatic safety lock while sensor is removed
  • Stainless steel AISI 316L / 1.4404 or Alloy
  • Immersion length up to 107mm
  • Usable in ATEX-areas
  • High variation of process connections and sealing materials
  • Hygienic design, EHEDG- / 3A-approved process connections
  • Extension of sensor-lifetime and reducing of maintenance efforts
  • Automatic safety lock while sensor is removed
  • Plug and play installation, colour- and size-coded connection system
  • Integrated limit switches
  • Usable in ATEX-areas
  • AISI 316L / 1.4404, surface finish Ra < 0.78 electropolished
  • Robust design, integrated PTFE scraper
  • Usable for DN25 welding socket
  • Extension of sensor-lifetime and reducing of maintenance efforts
  • Automatic safety lock while sensor is removed
  • Usable in ATEX-areas
  • Immersion length 70mm
  • Up to 10 bar and 140 °C
  • PP / PVDF or PEEK
  • Can be fully automated with electropneumatic control unit EXmatic 470
  • Drive unit free of maintenance
  • Robust design, integrated scraper
  • Extension of sensor-lifetime and reducing of maintenance efforts
  • Automatic safety lock while sensor is removed
  • Plug and play installation, colour- and size-coded connection system
  • Integrated limit switches
  • Usable in ATEX-areas
  • PVDF, PEEK
  • Robust design, integrated scraper
  • Extension of sensor-lifetime and reducing of maintenance efforts
  • Automatic safety lock while sensor is removed
  • Plug and play installation, colour- and size-coded connection system
  • Integrated limit switches
  • Usable in ATEX-areas
  • PP, PVDF, PEEK
  • Robust design, integrated PTFE scraper
  • Extension of sensor-lifetime and reducing of maintenance efforts
  • Automatic safety lock while sensor is removed
  • Plug and play installation, colour- and size-coded connection system
  • Integrated limit switches
  • Usable in ATEX-areas
  • Immersion length up to 90mm
  • Robust design, integrated scraper
  • Extension of sensor-lifetime and reducing of maintenance efforts
  • Automatic safety lock while sensor is removed
  • Plug and play installation, colour- and size-coded connection system
  • Integrated limit switches
  • Usable in ATEX-areas
  • Immersion length up to 207mm
  • Robust design, integrated scraper
  • Extension of sensor-lifetime and reducing of maintenance efforts
  • Automatic safety lock while sensor is removed
  • Plug and play installation, colour- and size-coded connection system
  • Integrated limit switches
  • Usable in ATEX-areas
  • Immersion length up to 107mm
  • Robust design
  • Integrated orbital sensor cleaning system
  • Extension of sensor-lifetime and reduction of maintenance efforts
  • Easy installation and removal of the sensor holder
  • PP or PVDF
  • Immersion length 500-2500mm
  • Minimum size DN50 / 2”
  • Up to 6 bar and 80 °C
  • No external cleaning devices necessary
  • Robust design
  • Integrated orbital sensor cleaning system
  • Extension of sensor-lifetime and reduction of maintenance efforts
  • Easy installation and removal of the sensor holder
  • Stainless steel AISI 316L / 1.4404
  • Immersion length 500-2500mm
  • Minimum size DN50 / 2”
  • Up to 10 bar and 140 °C
  • No external cleaning devices necessary
  • Replacement for US-sensors with NPT-thread
  • Stainless steel AISI 316L / 1.4404 / PVDF / PP
  • Sealing compounds EPDM / FPM (Viton) / FFKM (Kalrez)
  • Process connection NPT 3/4” or 1”
  • Optional sensor protection cage
  • Up to 10 bar and 140 °C
  • Designed according to hygienic criteria
  • Surface finish Ra<0,78 or Ra<0,37
  • Stainless steel AISI 316L / 1.4404
  • EPDM sealings with FDA and USP VI approval
  • Design process connections according to EHEDG / 3A
  • Up to 10 bar and 140 °C
  • Protection cap for cable connection
  • 15° angled process connection
  • Designed according to hygienic criteria
  • Surface finish Ra<0,78 or Ra<0,37
  • Stainless steel AISI 316L / 1.4404
  • EPDM sealings with FDA and USP VI approval
  • Design process connections according to EHEDG / 3A
  • Optional sensor protection cage
  • Up to 10 bar and 140 °C
  • Designed according to hygienic criteria
  • Surface finish Ra<0,78 or Ra<0,37
  • Stainless steel AISI 316L / 1.4404
  • EPDM sealings with FDA and USP VI approval
  • Optional sensor protection cage
  • Up to 10 bar and 140 °C
  • Protection cap for cable connection
  • Designed according to hygienic criteria
  • Surface finish Ra<0,78 or Ra<0,37
  • Stainless steel AISI 316L / 1.4404
  • EPDM sealings with FDA and USP VI approval
  • Optional sensor protection cage
  • Up to 10 bar and 140 °C
  • Protection cap for cable connection