Temperature Switches, Sensors & Transducers
- 25°C-110°C Set Points (5° increments)
- Max temperature 120°C
- Switch rating up to 250V
- 1/2” or 3/8” BSP thread(others available)
- Brass construction (stainless option)
- ATEX option available
- 35°C-85°C Set Points (5° increments)
- Max temperature 85°C
- Switch rating up to 250V
- 1/2” or 3/8” BSP thread(others available)
- Brass construction (stainless option)
- ATEX option available
- 0°C-200°C switching ranges
- Calibration accuracy ± 3°C
- Switch rating up to 240V
- 1/2” or 3/8” BSP thread
- Brass wetted parts
- Locking dial sets switch set-point
- 25°C-215°C Set Points
- Max temperature up to 300°C
- Switch rating up to 250V
- 1/2” or 3/8” BSP thread(others available)
- 123mm Brass bulb,2m stainless capillary
- Visual scale optional
- Output signal: analogic 4-20mA
- Supply voltage: 8-30V
- Case: AISI 316
- Working temperature: -20 / +100° C
- Protection degree: IP65 / IP67
- Electrical connection: M12
- Max Torque: 50 Nm
- 25°C-215°C Set Points
- Max temperature up to 300°C
- Switch rating up to 250V
- 1/2” or 3/8” BSP thread (others available)
- 123mm Brass bulb, 2m stainless capillary
- ATEX & IECEx approved
- 25°C-180°C Set Points (5° increments)
- Max temperature 240°C
- Switch rating up to 240V
- Wide choice of threads
- Brass construction
- Rated to 300 bar
- 40°C-120°C Set Points (10° increments)
- Max temperature 140°C
- Switch rating up to 250V
- 1/2” or 3/4” BSP thread
- Brass or stainless construction
- Rated to 100 bar
- Output signal: IO-Link
- Supply voltage: 24±10%
- Case: AISI 316
- Working temperature: -20 / +95° C
- Protection degree: IP65 / IP67
- Electrical connection: M12
- 25°C-215°C Set Points
- Max temperature up to 300°C
- Switch rating up to 250V
- 1/2” or 3/8” BSP thread(others available)
- 123mm Brass bulb,2m stainless capillary
- Visual scale optional
- Up to 170°C Set Points
- Max temperature 210°C
- Switch rating up to 250V
- 1/2” or 3/4” BSP thread
- Die Cast Aluminium
- ± 3°C Tolerance
- Thermoelements J, K, S
- Pt100 / Pt1000 / NTC resistance measurement
- 4..20 mA analogue output
- Universal input for Pt100, Pt1000, thermocouple, NTC and resistance measurement value
- Configuration via front DIP switches
- Analog actual value output 4 .. 20mA
- Zero point and limit value can be adjusted via trim potentiometers on the front
- Wide-range mains adapter or 24 V DCa
- Optional supply via carrier rail bus
- Removable coded screw terminals or optional push-in terminals
- Housing width 12.5 mm
- Carrier rail mounting TS35 EN60715
- Thermoelements J, K, S
- Pt100 Elements
- 0/2..10 V und 0/4..20 mA
- 4..20 mA analogue output
- Transmitter for electrical signals
- Universal input for standard signals, Pt100, thermocouple, potentiometer
- Configuration via front-side DIP switch
- Wide-range power supply or 24 V DC
- Housing width 12.5 mm
- Removal coded screw terminals
- Carrier rail mounting TS35 EN60715