{"title":"Light \u0026 UV Measurement","description":"\u003cp\u003ePortable meters and probes for illuminance, luminance, PAR, solar irradiance and UVA\/UVB\/UVC measurement from Senseca \/ Delta OHM.\u003c\/p\u003e","products":[{"product_id":"hd301-spectroradiometer-data-logger","title":"HD30.1 – Spectroradiometer Data Logger","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eThe HD30.1 spectroradiometer datalogger is designed for the \u003cstrong\u003espectral analysis of light in the visible range and ultraviolet.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe instrument has been designed by combining the maximum flexibility of use. The system \u003cstrong\u003econsists of two elements\u003c\/strong\u003e connected together by a cable: the \u003cstrong\u003edata logger-indicator\u003c\/strong\u003e HD30.1 and the \u003cstrong\u003emeasurement sensors\u003c\/strong\u003e (also available all toghether as a kit with code HD30.1K).\u003c\/p\u003e\n\u003cp\u003eThe analyzed spectral range varies according to the used measuring probe:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible Spectral Region\u003c\/strong\u003e (380 nm-780 nm) with the HD30.S1 probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltraviolet Spectral Region\u003c\/strong\u003e (220 nm-400 nm) with the HD30.S2 probe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMeasuring probes are interchangeable and calibrated (the calibration file is stored inside each probe).\u003c\/p\u003e\n\u003cp\u003eThe probe HD30.S1 analyzes the visible spectral region (380 nm-780 nm) and calculates the following photo-colorimetric quantities: \u003cstrong\u003eIlluminance\u003c\/strong\u003e [lux], \u003cstrong\u003eCorrelated Color Temperature CCT\u003c\/strong\u003e [K], \u003cstrong\u003eTrichromatic Coordinates\u003c\/strong\u003e [x,y] (CIE 1931) or [u',v'](CIE1978), \u003cstrong\u003eCRI\u003c\/strong\u003e (color rendering index, R1…R14, Ra) , \u003cstrong\u003ePAR\u003c\/strong\u003e [µmolphot\/sm²]\u003c\/p\u003e\n\u003cp\u003eThe probe HD30.S2 analyzes the ultraviolet spectral region (220 nm-400 nm) and calculates the following radiometric quantities: \u003cstrong\u003eUVA Irradiance\u003c\/strong\u003e (W\/m² ), \u003cstrong\u003eUVB Irradiance\u003c\/strong\u003e (W\/m² ) and \u003cstrong\u003eUVC Irradiance\u003c\/strong\u003e (W\/m²)\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178703982743,"sku":"8583","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/HD30.1_web.jpg?v=1654770617"},{"product_id":"lp471uvbc-uv-bc-irradiance-probe","title":"LP471UVBC – UV-BC Irradiance Probe","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eLP471UVBC is a \u003cstrong\u003eradiometric probe for measuring irradiance (W\/m²) in the 210…355 nm spectral range\u003c\/strong\u003e with peak at 265 nm. It is equipped with a connector with SICRAM module and a 2 m cable\u003c\/p\u003e\n\u003cp\u003eThe probe consists of a photodiode with an appropriate filter and is provided with a diffuser for correct measurement according to the cosine law. It is typically used in the verification of germicidal lamps used in sterilization systems working with LEDs as UV light sources.\u003c\/p\u003e\n\u003cp\u003eThe probe is available as well already combined in ready to use kits. Dependig on your needs, you can choose a basic one composed by the probe and our HD2102.2 portable luxmeter datalogger (UVBC-CK01-ACC).\u003c\/p\u003e\n\u003cp\u003eFor both solutions, the correctness of your measurements are also assured by the ISO 17025 Calibration Certificate issued in our own accredited Photo-radiometry laboratory.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178704998551,"sku":"13693","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LP471UVBC_AJ.jpg?v=1654770648"},{"product_id":"lpuvi02-series-uv-index-radiometric-probes","title":"LPUVI02… Series – UV Index Radiometric Probes","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eThe radiometer LPUVI02 measures the \u003cstrong\u003eglobal effective irradiance\u003c\/strong\u003e on a flat surface (Watt \/m² effective), according to the requirements of the WMO for the measurement of UV-index.\u003c\/p\u003e\n\u003cp\u003eThe global irradiance is the\u003cstrong\u003e sum of direct sun and of diffuse irradiance\u003c\/strong\u003e. In the ultraviolet spectral region, unlike what occurs in the portion of the visible light where the direct component is prevalent on the diffuse component, the light is strongly scattered in the atmosphere, and then the two components are equal; it is therefore of primary importance that the radiometer is able to accurately measure both components.\u003c\/p\u003e\n\u003cp\u003eThe radiometer LPUVI02 is produced with current output or voltage output:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVI02AC\u003c\/strong\u003e – 4…20 mA output (0…16 UV index).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVI02.1AC\u003c\/strong\u003e – 4…20 mA output (0…20 UV index).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVI02AV\u003c\/strong\u003e –  0…1 Vdc, 0…5 Vdc or 0…10 Vdc output  (0…16 UV index) to be defined when ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVI02.1AV\u003c\/strong\u003e – 0…1V dc, 0…5 Vdc or 0…10 Vdc output (0…20 UV index) to be defined when ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe versions 02.1 have a full scale that reach 20 UV-index and are suitable for the measurement of UV in equatorial areas and high mountain: in these places in fact  index value UV of 11 can be exceeded for a significant time.\u003cbr\u003e\nThe power supplied is required at 8-30 Vdc, except for the version LPUVI02AV10 (voltage output 0-10 V) which is of 15-30 Vdc.\u003c\/p\u003e\n\u003cp\u003eThe instrument is managed to operate for long periods without maintenance (except cleaning of the dome and checking the status of silica gel) provided that it is properly powered.\u003c\/p\u003e\n\u003cp\u003eThis feature makes the device ideal for use in\u003cstrong\u003e remote weather stations\u003c\/strong\u003e also.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178705621143,"sku":"8588","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LPUVIndex-1.jpg?v=1654770666"},{"product_id":"hd21021-portable-luxmeter","title":"HD2102.1 – Portable Luxmeter","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003ePortable handheld luxmeter for measuring\u003cstrong\u003e illuminance, luminance, PAR, irradiance\u003c\/strong\u003e (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).\u003c\/p\u003e\n\u003cp\u003eIn addition to instantaneous measurement, the instrument calculates the acquired measurements time integral Q(t).\u003c\/p\u003e\n\u003cp\u003eStorage of maximum, minimum, average value and the integral Q(t). RS232 C output for data transfer in real time to a PC or printer.\u003c\/p\u003e\n\u003cp\u003eFunctions: REL, HOLD and auto power off which can be disabled, IP 66 protection degree.\u003c\/p\u003e\n\u003cp\u003eIncludes DeltaLog9 software downloadable \u003cstrong\u003ehere\u003c\/strong\u003e. Supplied with carrying case, instruction manual, 4 batteries.\u003c\/p\u003e\n\u003cp\u003eLP471…  probes with SICRAM module are suitable. The probes and cables for data download have to be ordered separately.\u003c\/p\u003e\n\u003cp\u003eAvailable as well with datalogging function HD2102.2.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178716893335,"sku":"11728","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/HD2102.1-Portable-luxmeter-1.jpg?v=1654770959"},{"product_id":"hd21022-portable-luxmeter-data-logger","title":"HD2102.2 – Portable Luxmeter Data Logger","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003ePortable handheld luxmeter data logger for measuring\u003cstrong\u003e illuminance, luminance, PAR, irradiance\u003c\/strong\u003e (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).\u003c\/p\u003e\n\u003cp\u003eIn addition to instantaneous measurement, the instrument calculates the acquired measurements time integral Q(t). It stores up to 38,000 samples with a one-channel probe and up to 14,000 samples with combined probes. These data can be transferred from the instrument to a PC via the connection of the multi-standard RS232C serial port and USB 2.0.\u003c\/p\u003e\n\u003cp\u003eStoring interval, printing and baud rate can be configured by using the menu. Storage of maximum, minimum, average value and the integral Q(t), RS232 C output for data transfer in real time to a PC or printer.\u003c\/p\u003e\n\u003cp\u003eFunctions: REL, HOLD and auto power off which can be disabled, IP 66 protection degree.\u003c\/p\u003e\n\u003cp\u003eIncludes DeltaLog9 software downloadable\u003cstrong\u003e here\u003c\/strong\u003e. Supplied with carrying case, instruction manual, 4 batteries, CP23 USB cable.\u003c\/p\u003e\n\u003cp\u003eLP471… series probes with SICRAM module are suitable. The probes have to be ordered separately.\u003c\/p\u003e\n\u003cp\u003eAvailable as well without data logging function HD2102.1.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178717253783,"sku":"11731","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/HD2102.2-Portable-luxmeter-data-logger-1.jpg?v=1654770970"},{"product_id":"hd23020-portable-luxmeter","title":"HD2302.0 – Portable Luxmeter","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003ePortable luxmeter for measuring \u003cstrong\u003eilluminance, luminance, PAR, irradiance\u003c\/strong\u003e (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).\u003c\/p\u003e\n\u003cp\u003eStorage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree.\u003c\/p\u003e\n\u003cp\u003eLP471 series probes with SICRAM module are suitable.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178717941911,"sku":"11725","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/HD2302.0-portable-luxmeter-3.jpg?v=1654770991"},{"product_id":"lp471phot-illuminance-probe","title":"LP471PHOT – Illuminance Probe","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003ePhotometric probe for measuring the \u003cstrong\u003eILLUMINANCE\u003c\/strong\u003e, spectral response according to the photopic curve, class B according to CIE N° 69, cosine correction diffuser.\u003c\/p\u003e\n\u003cp\u003eMeasuring range: 0.10 lux…200·10³ lux.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178727411863,"sku":"11738","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LP471PHOT-illuminance-probe_937c447b-0ea5-478b-8bc2-a17670f677f2.jpg?v=1654771248"},{"product_id":"lpuva02-radiometric-probe-for-irradiance","title":"LPUVA02 – Radiometric Probe for Irradiance","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eRadiometric probe for outdoor use for measuring \u003cstrong\u003eIRRADIANCE in the UVA spectral range (315…400 nm)\u003c\/strong\u003e.  Supplied with Calibration Report. On request CPM12AA4… cables with 4-pole M12 connector.\u003c\/p\u003e\n\u003cp\u003eThe LPUVA02 radiometer measures the broadband UVA irradiance on a plane surface (Watt\/ m²). Measured irradiance is the result of the sum of direct solar\u003cbr\u003e\nirradiance and of diffuse irradiance. TIt can measure as well the UVA irradiance in closed room.\u003c\/p\u003e\n\u003cp\u003eThe radiometer is produced in three versions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVA02\u003c\/strong\u003e – passive – μV per μW\/cm² output;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVA02AC\u003c\/strong\u003e – active, 4…20 mA current output (0…150 W\/m²), integrated transmitter amplifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVA02AV\u003c\/strong\u003e – active, 0…1Vdc, 0…5Vdc or 0…10Vdc output (0…150 W\/m²) to be defined when ordering, integrated transmitter amplifier.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178728886423,"sku":"11870","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LPUVA02-irradiance-1.jpg?v=1654771310"},{"product_id":"lpuvb01-irradiance-probe","title":"LPUVB01 – Irradiance Probe","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eLPUVB01\u003c\/strong\u003e probe measures irradiance (W\/m\u003csup\u003e2\u003c\/sup\u003e) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m\u003csup\u003e2\u003c\/sup\u003e) in the UVB (280 nm …315 nm) spectral range.\u003c\/p\u003e\n\u003cp\u003eThanks to a new type of photodiode, LPUVB01 is blind to visible and infrared light. Probe calibration is carried out by using a 313 nm line of a Xe-Hg lamp, filtered through a special interferential filter.\u003c\/p\u003e\n\u003cp\u003eMeasurement is carried out by comparison with the primary standards, assigned to Delta OHM Metrological Laboratory.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178729148567,"sku":"9783","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LP_01-light-probes-1_799b68db-8d5d-4cd0-9f14-3883b4dff2a2.jpg?v=1654771319"},{"product_id":"lpuva03series-radiometric-probe-for-uva-irradiance","title":"LPUVA03…Series – Radiometric Probe for UVA Irradiance","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eLPUVA03\u003c\/strong\u003e probe measures irradiance (W\/m²) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m²) in the UVA (315 nm…400 nm) spectral range. Thanks to a new type of photodiode, LPUVA03 is blind to visible and infrared light.\u003c\/p\u003e\n\u003cp\u003eProbe calibration is carried out by using a 365 nm line of a Xe-Hg, filtered through a special interferential filter. Measurement is carried out by comparison with the primary standards, assigned to Delta OHM Metrological Laboratory.\u003c\/p\u003e\n\u003cp\u003eThe probe is designed for \u003cstrong\u003eoutdoor readings\u003c\/strong\u003e. Output, according to the chosen configuration, in μV per μW\/cm² or 4…20 mA or 0…10 Vdc normalized output or RS485 MODBUS-RTU output.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVA03\u003c\/strong\u003e = μV\/(μW\/cm²) output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVA03BL\u003c\/strong\u003e = μV\/(μW\/cm²) output + base with levelling device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVA03BLAC\u003c\/strong\u003e = output 4…20 mA + base with levelling device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVA03BLAV\u003c\/strong\u003e = output 0…10 V + base with levelling device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLPUVA03BLS\u003c\/strong\u003e = RS485 MODBUS-RTU output + base with levelling device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWorking temperature -20…+60 °C.  M12 male 4-pole (models with analog output) or 8-pole (model with RS485 MODBUS-RTU output) connector.\u003c\/p\u003e\n\u003cp\u003eOn request CPM12AA4… (except LPUVA03BLS) or CPM12-8D (only LPUVA03BLS) cable with M12 female connector.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178730033303,"sku":"8476","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LP_03serie_89449f4a-c06f-47e2-9343-d19533453149.jpg?v=1654771346"},{"product_id":"lp471siliconpyra-pyranometer-with-silicon-photodiode","title":"LP471SILICONPYRA – Pyranometer with Silicon Photodiode","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003ePyranometer with silicon photodiode to measure the \u003cstrong\u003eGLOBAL SOLAR IRRADIANCE\u003c\/strong\u003e, diffuser for cosine correction.\u003c\/p\u003e\n\u003cp\u003eSpectral range: 400…1100 nm.\u003c\/p\u003e\n\u003cp\u003eMeasuring range: 1 mW\/m²…2000 W\/m². Fixed cable 5m long, with SICRAM module.\u003c\/p\u003e\n\u003cp\u003eThe probe can be connected to the instruments HD2102.2 (from 05\/2012).\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178730688663,"sku":"10272","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LP-471SILICON-PYRA_38cb88e3-a941-4652-8f6e-0d9386ff60ff.jpg?v=1654771359"},{"product_id":"lp471par-par-quantum-radiometric-probe","title":"LP471PAR – PAR Quantum Radiometric Probe","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eQuantum-radiometric probe for measuring the \u003cstrong\u003ePHOTONS FLOW\u003c\/strong\u003e in the chlorophyll field \u003cstrong\u003ePAR\u003c\/strong\u003e (photosynthetically Active Radiation 400nm…700 nm), μmol m-²s-¹ measure, cosine correction diffuser.\u003c\/p\u003e\n\u003cp\u003eMeasuring range 0.10 μmol m-²s-¹…10·10³ μmol m-²s-¹.\u003c\/p\u003e\n\u003cp\u003eAvailable also probe LP471PAR02 that uses a special filter that optimizes the spectral response.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178737045655,"sku":"11742","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LP471PAR-PAR-probe_87ecb571-f0cd-4d56-8073-ac27f93cbd84.jpg?v=1654771591"},{"product_id":"lpuva01-irradiance-probe","title":"LPUVA01 – Irradiance Probe","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eLPUVA01\u003c\/strong\u003e probe measures irradiance (W\/m\u003csup\u003e2\u003c\/sup\u003e) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m\u003csup\u003e2\u003c\/sup\u003e) in the UVA (315 nm … 400 nm) spectral range.\u003c\/p\u003e\n\u003cp\u003eThanks to a new type of photodiode, LPUVA01 is blind to visible and infrared light.\u003c\/p\u003e\n\u003cp\u003eProbe calibration is carried out by using a 365 nm line of a Xe-Hg lamp, filtered through a special interferential filter. Measurement is carried out by comparison with the primary standards, assigned to Delta OHM Metrological Laboratory.\u003cbr\u003e\nThis probe can be used in all processes where ultraviolet lamp emission needs to be monitored: resins and adhesives polymerization, as well as tanning lamps.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178740748439,"sku":"9782","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LP_01-light-probes-1_ad2389a3-ccf0-4b68-a790-2665b9bef562.jpg?v=1654771716"},{"product_id":"lpuvc01-irradiance-probe","title":"LPUVC01 – Irradiance Probe","description":"\u003cdiv class=\"panel entry-content\" id=\"tab-description\" style=\"\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eLPUVC01\u003c\/strong\u003e probe measures irradiance (W\/m\u003csup\u003e2\u003c\/sup\u003e) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m\u003csup\u003e2\u003c\/sup\u003e) in the UVC (200 nm…280 nm) spectral range.\u003c\/p\u003e\n\u003cp\u003eThanks to a new type of photodiode, LPUVC01 is blind to visible and infrared light.\u003c\/p\u003e\n\u003cp\u003eThe probe calibration is carried out by measuring irradiance coming from an Hg lamp at 254 nm.\u003c\/p\u003e\n\u003c\/div\u003e\u003ch3\u003eProduct Catalogue\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/pvl.co.uk\/pages\/the-big-cat-multitool\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/files\/Sign_Up_for_our_Exclusive_Catalogue_1.png?v=1759826864\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Delta OHM","offers":[{"title":"Default Title","offer_id":42178752053399,"sku":"9784","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/0088\/0535\/products\/LP_01-light-probes-1_78dd894f-4416-40e9-ae7e-bdeb829548f1.jpg?v=1654771915"}],"url":"https:\/\/pvl.co.uk\/collections\/light-uv-measurement.oembed","provider":"PVL","version":"1.0","type":"link"}